loader image
RRH Serisi Yüksek Basınç Türbin Debimetre gallery image 1
RRH Serisi Yüksek Basınç Türbin Debimetre gallery image 1

RRH Serisi Yüksek Basınç Türbin Debimetre

Uncomplicated measurement of flow rates

Metal housing with Hall sensor

Working pressure up to 100 bar

Long working life thanks to high quality ceramic axis and

Special plastic bearing

Run-in and run-out sections are not necessary.

Modular construction with various

Connection systems

Plug-in and rotatable connections

Output signal PNP or NPN

Intrinsically safe behaviour

Optionally, non-return valve, filter, constant flow rate

Device in the connection

Türler

Qmax

Metering range

Pulses/litre

Frequency

RRH

l/dk H2O

l/dk H2O

Hz

-1

-2

-3

010...020

1,8

0.1 .. 1.5

0.5.. 1.5

0.1..0.5

4955

124

010...050

12

0.2 ..10.0

2.0..  10

0.2..2.0

1632

272

010...070

14,4

0.4 ..12.0

2.0.. 12

0.4..2.0

860

172

025...080

36

2.0 ..30.0

3.0..  30

2.0..3.0

544

272

025...120

72.0

3.0 ..60.0

5.0..  60

3.0..5.0

295

295

025...160

120

4.0 .. 100.0

6.0..100

4.0..6.0

126

210

(1) Complete metering range

(2) Specific metering range

(3) Start-up range

Sensor : hall element

Nominal width : DN 10 (RRH-010), DN 25 (RRH-025)

Mechanical Connection : female thread G 3/8, G 1 male thread G 3/8 A, G 1 A hose nozzle Ø11, Ø30

(other threaded, crimped, and plug-in connections, connections with constant flow rate device or limiters available on request)

Pressure resistance : PN 100 bar

Metering ranges : see table “Ranges”

Medium temperature : 0..100 °C

Current consumption : 30 mA

Output current max. : 100 mA

Electrical connection cable : 2 m or for round plug connector M12x1, 4-pole

Resistant to short circuits : yes

Reversal polarity protected : yes

Ingress protection : IP 67