loader image
OMNI VHS Serisi Vidalı Debimetre gallery image 1
OMNI VHS Serisi Vidalı Debimetre gallery image 1

OMNI VHS Serisi Vidalı Debimetre

Sensor : screw volumeter

Nominal width : DN 25..65

Process connection : female thread G 1..G 21/2

Metering ranges : see table “Ranges and weights”

Measurement accuracy : ±1 % of the measured value (at 20 mm²/s, (cSt) of 1 %..100 % nominal working range (see also diagram in

Repeatability : ±0,25 %

: Connection material

: Aluminium

Pressure resistance : Aluminium
: Steel
: Steel others available on request

Pressure loss : see diagram in upstream pages

Medium : oil or non-aggressive self-lubricating fluids

Medium temperature : -25..+80 °C (150 °C available on request)

Supply voltage : 18..30 V DC

Power consumption : < 1 W

Analog output : 4..20 mA / max. load 500 Ω or 0..10 V / min. load 1 kΩ

Switching outputs : transistor output "push-pull"
: (resistant to short circuits and polarity reversal) Iout = 100 mA max.

Hysteresis : adjustable, position of the hysteresis depends on minimum or maximum

Display : backlit graphical LCD-Display
: (transreflective), extended temperature range -20..+70 °C, 32 x 16 pixels, background illumination, displays value and unit, flashing LED signal lamp with simultaneous message on the display.

Electrical connection : for round plug connector M12x1, 5-pole

Ingress protection : IP 67 / (IP 68 when oil-filled)

G

DN

Metering range

Volume / pulse

Types

Qmax

Body with aluminium connections

Weights

SAE

1..100 %

recommended

Flanges

Qnom

l/min

cm³

l/min

kg

kg

kg

G 1

DN 25

l

1.4..  140

13.10

OMNI-VHS-025.....0140

200

3.44

4.76

5.76

G 11/4

DN 32

l

3.5..  350

29.00

OMNI-VHS-032.....0350

500

6.35

8.50

9.55

G 11/2

DN 40

m

5.5..  550

48.58

OMNI-VHS-040.....0550

800

10,5

13,6

15,1

l

8.0..  800

72.00

OMNI-VHS-040.....0800

1200

14,2

18,5

18,8

G 2

DN 50

m

10.0..1000

103,63

OMNI-VHS-050.....1000

1600

20,7

27,7

30,3

l

15.0..1500

133

OMNI-VHS-050.....1500

2200

25

33,2

34,6

G 21/2

DN 65

l

25.0..2500

238,82

OMNI-VHS-065.....2500

3800

42,7

56,1

60,7

Measures and monitors viscous media (oil) 1.4..2500 l/min
Connection G 1..G 21/2
Very low dependence on viscosity
Can be used up to 40,000 mm²/s (cSt)
Light and compact device (aluminium housing)
Operation and measurement possible with forwards and reverse flow
For cost-sensitive applications
● Analog output 4..20 mA or 0..10 V
● Two programmable switches
Graphical LCD display, backlit, can be read in sunlight and in the dark
able units in the display
Programmable parameters via rotatable, removable ring (programming protection)
Electronics housing with non-scratch, chemically resistant glass
Rotatable electronic housing for best reading position
Designed for industrial use
Small, compact construction
● Simple installation