loader image
VSV-M VSV-F Coaxsial Solenoid Vana gallery image 1
VSV-M VSV-F Coaxsial Solenoid Vana gallery image 1

VSV-M VSV-F Coaxsial Solenoid Vana

Order

Orifice

Threaded

Connection

Flange

Pressure

Kv

Fluid

Environment

Temperature

Open Close [ms]

No

[mm]

Size

Connection Size

[bar]

Value

Temperature

A > B

VSV- M / VSV- F 40

DN 40

G 1 1 /2 - G2

PN 16 / 40

0 - 16 / 40

31.0 m³ /h

-20 °C ... +160 °C

-20 °C ... +160 °C

100 / 3000

VSV- M / VSV- F 50

DN 50

G 2

PN 16 / 40

0 - 16 / 40

43.0 m³ /h

-20 °C ... +160 °C

-20 °C ... +160 °C

150 / 3000

VSV- F 65

DN 65

-

PN 16 / 40

0 - 16 / 40

68,0 m³ / h

-20 °C ... +160 °C

-20 °C ... +160 °C

200 / 3000

VSV- F 80

DN 80

-

PN 16 / 40

0 - 16 / 40

90,0 m³ /h

-20 °C ... +160 °C

-20 °C ... +160 °C

200 / 3000

VSV- F 100

DN 100

-

PN 16 / 40

0 - 16 / 40

140,0 m³ / h

-20 °C ... +160 °C

-20 °C ... +160 °C

300 / 3000

VSV- F 125

DN 125

-

PN 16 / 40

0 - 16 / 40

196,0 m³ / h

-20 °C ... +160 °C

-20 °C ... +160 °C

400 / 3000

VSV- F 150

DN 150

-

PN 16 / 40

0 - 16 / 40

274,0 m³ / h

-20 °C ... +160 °C

-20 °C ... +160 °C

600 / 3000

VSV- F 200

DN 200

-

PN 16

0 - 16

450,0 m³ / h

-20 °C ... +160 °C

-20 °C ... +160 °C

800 / 3000

VSV- F 250

DN 250

-

PN 16

0 - 16

650,0 m³ / h

-20 °C ... +160 °C

-20 °C ... +160 °C

1500 / 3000

Operation : Pressure Balanced spring return system.

Position : NC - normally closed, NO - normally open

Body materials : Aluminum, brass, galvanized steel, nickel plated brass, nickel-plated steel, nonmagnetic metal, stainless steel

Sealing element : NBR, PTFE, FPM, EPDM, different sealing element for special applications.

Working pressure : PN 0 - 40 bar

Fluid : Gases, liquids, gels, high viscosity liquid, paste and paste, corrosive fluids, acid

Working Operation : Pneumatic 5/2 Way namur solenoid valve or hydraulic 4/2 control valve

Control Valve : Assembly NAMUR ISO 1

Operating voltage : 24 V DC / AC 230 V

Socket : Plug acc. DIN EN 175301-803, form A, LED

Protection Class : IP 65

Continuous duty : ED 100%

Flow Direction : A> B, B> A (delta p 16 bar max.) In both directions

Vacuum : Leak rate <10-6 mbar · l · s-1

Option : Special threaded fasteners, special flanged connection, normally open position, damping, limit switches, control unit, approved document, special voltage, plug M 12 x 1, terminal box. Explosion Proof ATEX zone 1 and zone 2