loader image
TORK-EX GA22 Series ATEX Exprood Certified Dry Contact Gas Alarm Device gallery image 1
TORK-EX GA22 Series ATEX Exprood Certified Dry Contact Gas Alarm Device gallery image 1

TORK-EX GA22 Series ATEX Exprood Certified Dry Contact Gas Alarm Device

Detecting Gasses : Natural Gas (methane), LPG (Liquefied Petroleum Gas)

Sensor Type : Semiconductor (5V±0,1)

Main Body Material : Aluminum

Calibration Time : 1,5 minutes

Reaction Time : <10 seconds

Audible Warnings : Piezoelectric Buzzer

Volume : 85dB

Operating Voltage : 12V DC

Output Signal(Relay Contact : 5A 30VDC NO

Power Consumption : 3W

Operating Area : Industrial Kitchens, Boiler rooms, Gasoline stations etc…

Sensor Protection Class : II G Ex d IIB T6 IP65

Operating Temparature : -10°C….+50°C

Relative Humidity : 0-95%

Estimated Device Life : 5 years

Referans Standarts : TS EN 50194-1, TS EN 60079-0, TS EN 60079-18

What is the TORK EX GA22 Series ATEX Gas Alarm Device with Dry Contact Output? Intelligent Gas Safety for Hazardous Environments

The production, storage, and processing of gases such as natural gas, LPG, propane, and butane in industrial facilities require highly sensitive safety measures. Potential gas leaks in these environments can lead to fires, explosions, workforce losses, and costly production shutdowns. Minimizing such risks is only possible through the integration of intelligent gas detection systems that comply with international standards and are capable of initiating proactive safety actions.

The TORK EX GA22 Series ATEX Gas Alarm Device with Dry Contact Output is an industrial safety solution specifically developed for hazardous and potentially explosive atmospheres (Ex-proof environments). With its microprocessor-based sensor technology, high protection rating, and relay architecture designed for seamless automation integration, it provides a reliable and uninterrupted gas safety infrastructure for modern facilities.

What Is an ATEX Gas Alarm Device with Dry Contact Output?

ATEX gas alarm devices are specially certified safety instruments designed for hazardous areas such as Zone 1 and Zone 2, where combustible gases may mix with air and create explosive atmospheres. These devices are engineered to prevent ignition by isolating potential sparks generated within their electrical circuits.

The system’s dry contact output (NO/NC) enables the device to function as more than just an audible and visual alarm. When a gas leak is detected, the relay mechanically activates or deactivates connected safety equipment without directly supplying external voltage. The TORK EX GA22 Series combines these two critical technologies in a single industrial-grade device, delivering proactive protection for hazardous applications.

Real-Time Safety Scenario

Imagine a natural gas leak occurring in an industrial boiler room, causing gas concentration levels to reach the critical threshold of 20% LEL.

Detection

The TORK EX GA22 detects the leak within seconds.

Local Alarm

The red LED indicator enters flashing mode, while the integrated high-decibel buzzer activates.

Automatic Gas Shut-Off

The dry contact relay is immediately triggered, sending a signal to the connected TORK Gas Shut-Off Solenoid Valve, which automatically closes the main gas supply line.

Ventilation Activation

Through the same relay output, explosion-proof ventilation fans are activated to safely evacuate hazardous gases from the environment.

SCADA Integration

Alarm signals are transmitted to the facility’s PLC/SCADA system, providing operators with immediate visual notification in the central control room.

Advantages of Dry Contact Output in Facility Management

Within industrial automation ecosystems, the TORK EX GA22 can communicate seamlessly with numerous safety and control systems.

Gas Shut-Off Solenoid Valves

Automatically isolates gas lines to prevent fire escalation.

Forced Ventilation and Exhaust Systems

Activates jet fans and ventilation equipment to remove hazardous gases.

Central Fire Alarm and Warning Panels

Integrates with building-wide emergency response scenarios.

PLC, SCADA, and Building Management Systems (BMS)

Provides digital I/O signals for remote monitoring and control through industrial automation platforms.

Key Advantages of the TORK EX GA22

Cross-Sensitivity Prevention (False Alarm Reduction)

Advanced sensor technology minimizes false alarms caused by cleaning chemicals, alcohol vapors, or other non-target gases, reducing unnecessary downtime.

Easy Maintenance and Calibration

The replaceable intelligent sensor head simplifies calibration procedures and minimizes service interruptions.

Designed for Harsh Industrial Conditions

The robust housing is resistant to humidity, dust, high temperatures, and aggressive chemical environments.

Economical Continuous Operation

Low power consumption enables reliable 24/7 operation while optimizing operating costs.

Applications of the TORK EX GA22

Industrial and Residential Boiler Rooms

Natural gas-based heating and energy systems.

Chemical, Petrochemical, and Paint Facilities

Areas where flammable raw materials and solvents are processed or stored.

LPG Filling, Storage, and Distribution Stations

Tank farms, transfer points, and gas distribution facilities.

Industrial Kitchens

Hotels, restaurants, hospitals, and factory kitchens.

Logistics and Warehousing Facilities

Storage areas for chemical products and flammable gas cylinders.

Steel Plants and Power Generation Facilities

Industrial processes involving high temperatures and intensive gas usage.

Conclusion and System Integration

Using conventional gas alarm devices in hazardous environments containing explosive gases is neither compliant with safety regulations nor sufficient for protecting personnel and assets.

The TORK EX GA22 Series ATEX Gas Alarm Device with Dry Contact Output is an essential component of modern industrial safety systems, offering full compliance with ATEX directives, fast response time (T90), and automation-friendly dry contact functionality. It not only detects danger but also initiates immediate protective actions to prevent incidents before they escalate.