loader image
S1011 General Purpose Solenoid Valve gallery image 1
S1011 General Purpose Solenoid Valve
S1011 General Purpose Solenoid Valve gallery image 1
S1011 General Purpose Solenoid Valve

S1011 General Purpose Solenoid Valve

Application : Air, water, gas

Size : 1/8", 1/4" Direct acting; 3/8"…2" Pilot operated

Working Pressure : 0..14 bar (1/8", 1/4"); 0,5 bar..12 bar (3/8"…2")

Core Tube : Stainless

Body : Brass

Seal : NBR, on request EPDM, VITON

Working Temperature : -10°C…80 °C

Position : Normally Open

Coil Voltage : 230V, 110V , 48V, 24V , 12V AC ; 110V , 48V , 24V , 12 V DC

Protection Class : IP65 (on request Exproof)

Product

Code

Connection

Size

Orifice

Size (mm)

Pressure (bar)

Kv

lt/min

Seal

/Oring

Weight (kg)

Min

Max

Option

S1011.00.010

1/8"

1

0

14

0,5

NBR

Viton

EPDM

0,36

S1011.00.018

1/8"

1,8

0

12

1,6

NBR

Viton

EPDM

0,36

S1011.00.025

1/8"

2,5

0

10

3,2

NBR

Viton

EPDM

0,36

S1011.00.030

1/8"

3

0

5

4,6

NBR

Viton

EPDM

0,36

S1011.01.010

1/4"

1

0

14

0,5

NBR

Viton

EPDM

0,36

S1011.01.018

1/4"

1,8

0

12

1,6

NBR

Viton

EPDM

0,36

S1011.01.025

1/4"

2,5

0

10

3,2

NBR

Viton

EPDM

0,36

S1011.01.030

1/4"

3

0

5

4,6

NBR

Viton

EPDM

0,36

S1011.02

3/8"

12,5

0,5

12

48

NBR

Viton

EPDM

0,69

S1011.03

1/2"

14,5

0,5

12

70

NBR

Viton

EPDM

0,73

S1011.04

3/4"

17

0,5

12

90

NBR

Viton

EPDM

0,81

S1011.05

1"

17

0,5

12

90

NBR

Viton

EPDM

0,98

S1011.06

1 1/4"

30

0,5

12

250

NBR

Viton

EPDM

2,65

S1011.07

1 1/2"

39

0,5

12

370

NBR

Viton

EPDM

2,55

S1011.08

2"

46

0,5

12

450

NBR

Viton

EPDM

2,98

S1011 General Purpose Solenoid Valves are normally open and tubeless. 1/8 ”… 1/4” direct acting, 3/8 ”… 2” pilot operated.
In normally open solenoid valves, fluid passes through the valve body when the coil is not energized. When the coil is energized, the valve is normally closed and the fluid stops flow. S1011 Series normally open position solenoid valves are preferred if the valve will remain in the normally open position for such a long time. 
It is suitable for air, water, gas fluids. The use of filters is recommended for dirty and particulate fluids. It is used in sectors such as refining, paint industry, cement, machine manufacturers and ceramics.
Solenoid valves are preferred in fluid control due to their compact structure, fast activation and deactivation, low energy consumption and long life.