loader image
C95 Series Pulse Valve Timer gallery image 1
C95 Series Pulse Valve Timer gallery image 1

C95 Series Pulse Valve Timer

Standby time : 0.5 min... 45 min

Emptying time : 0.5 sec 10 sed

Ambient temperature : -40..60 degree

Body material : ABS plastic, set industry plastic

Working voltage : 24V DC or 240V AC 50Hz

Current : 7 mA

Display : LED (on-off)

Protection class : IP65 Socket ( on request IP68 or ATEX)

Manual Reset : Var

C95 Series Multi-Output Timer Relay, 220V AC Operating Voltage
C95.0.08 – 220V AC, 8 relay outputs

C95.0.16 – 220V AC, 16 relay outputs

C95.0.24 – 220V AC, 24 relay outputs

C95.0.32 – 220V AC, 32 relay outputs

C95.0.40 – 220V AC, 40 relay outputs

C95 Series Multi-Output Timer Relay, 24V DC Operating Voltage
C95.0.08 – 24V DC, 8 relay outputs

C95.0.16 – 24V DC, 16 relay outputs

C95.0.24 – 24V DC, 24 relay outputs

C95.0.32 – 24V DC, 32 relay outputs

C95.0.40 – 24V DC, 40 relay outputs

C95 Series Multi-Output Timer Relay with Differential Pressure Sensor, 220V AC
C95.1.08 – 220V AC, 8 relay outputs

C95.1.16 – 220V AC, 16 relay outputs

C95.1.24 – 220V AC, 24 relay outputs

C95.1.32 – 220V AC, 32 relay outputs

C95.1.40 – 220V AC, 40 relay outputs

C95 Series Multi-Output Timer Relay with Differential Pressure Sensor, 24V DC
C95.1.08 – 24V DC, 8 relay outputs

C95.1.16 – 24V DC, 16 relay outputs

C95.1.24 – 24V DC, 24 relay outputs

C95.1.32 – 24V DC, 32 relay outputs

C95.1.40 – 24V DC, 40 relay outputs

C95 Series Multi-Output Timer Relay with 4–20 mA Analog Input, 220V AC
C95.2.08 – 220V AC, 8 relay outputs

C95.2.16 – 220V AC, 16 relay outputs

C95.2.24 – 220V AC, 24 relay outputs

C95.2.32 – 220V AC, 32 relay outputs

C95.2.40 – 220V AC, 40 relay outputs

C95 Series Multi-Output Timer Relay with 4–20 mA Analog Input, 24V DC
C95.2.08 – 24V DC, 8 relay outputs

C95.2.16 – 24V DC, 16 relay outputs

C95.2.24 – 24V DC, 24 relay outputs

C95.2.32 – 24V DC, 32 relay outputs

C95.2.40 – 24V DC, 40 relay outputs

C95 Series Multi-Output Timer Relay with 0–10 V DC Analog Input, 220V AC
C95.3.08 – 220V AC, 8 relay outputs

C95.3.16 – 220V AC, 16 relay outputs

C95.3.24 – 220V AC, 24 relay outputs

C95.3.32 – 220V AC, 32 relay outputs

C95.3.40 – 220V AC, 40 relay outputs

C95 Series Multi-Output Timer Relay with 0–10 V DC Analog Input, 24V DC
C95.3.08 – 24V DC, 8 relay outputs

C95.3.16 – 24V DC, 16 relay outputs

C95.3.24 – 24V DC, 24 relay outputs

C95.3.32 – 24V DC, 32 relay outputs

C95.3.40 – 24V DC, 40 relay outputs

What Is the C95 Series Multi-Output Pulse Valve Timer Controller?

The Smart Control Solution for Pulse Jet Filter Systems

In industrial dust collection systems, pulse valves must be operated at precise intervals and with millisecond accuracy to maintain filter performance and overall operational efficiency. Managing filter cleaning cycles manually or with conventional timers often results in excessive compressed air consumption, premature filter bag wear, and increased energy costs.

The C95 Series Multi-Output Pulse Valve Timer Controller is a next-generation industrial automation unit designed to provide automatic, synchronized, and intelligent control of pulse valves in pulse jet filtration systems.

What Is a Pulse Valve Timer Controller and Why Is It Important?

A pulse valve timer controller is an electronic control device that manages the opening and closing sequences, pulse durations, and pause intervals of pulse valves used for cleaning baghouse filters.

This control system directly affects dust collection performance and provides several important benefits:

Smart Automation

Filter cleaning cycles are managed automatically without operator intervention.

Minimum Compressed Air Consumption

Compressed air usage is optimized, reducing compressor workload and operating costs.

Maximum Filter Bag Life

Properly timed cleaning cycles prevent premature wear, tearing, and damage to filter bags.

Lower Operating Costs

Eliminating unnecessary compressed air consumption helps reduce electricity expenses.

Continuous Production

Filter clogging is prevented, ensuring uninterrupted plant operation and production continuity.

How Does the C95 Series Timer Controller Work?

The C95 Series Timer Controller sequentially activates pulse valves connected to the filtration system according to user-defined pulse and pause times.

Precise Programming

Users can easily configure pulse duration in milliseconds and pause intervals in seconds or minutes via the control panel.

Sequential Triggering

Each output channel sends signals to the corresponding pulse valve in sequence.

Pulse Cleaning Action

The pulse valve releases a high-pressure burst of compressed air, shaking the filter bag and removing accumulated dust cake.

Continuous Automatic Cycle

The controller continuously repeats the cleaning sequence to maintain optimum filter permeability and performance.

Intelligent Energy Management: Differential Pressure and Analog Input Models

The C95 Series is available in several advanced versions designed to meet different automation requirements.

1. Differential Pressure (Delta P) Controlled Models

These models continuously monitor the pressure difference between the clean-air and dirty-air chambers of the filter system.

As long as the differential pressure remains below the configured threshold, the cleaning cycle does not start.

Benefits include:

  • Up to 50% reduction in compressed air consumption
  • Reduced filter bag wear
  • Improved energy efficiency

2. 4–20 mA Analog Input Models

Designed to process signals from industrial transmitters and field sensors, enabling dynamic and highly accurate cleaning control.

3. 0–10 V Analog Input Models

Ideal for smart factory applications requiring full integration with central PLC and SCADA automation systems.

Applications and Industries

The C95 Series Multi-Output Pulse Valve Timer Controller is widely used in industries where high dust emissions and continuous filtration performance are critical.

Cement and Gypsum Plants

Steel Mills and Metal Smelting Facilities

Mining, Ore Processing, and Crushing & Screening Plants

Chemical, Paint, and Plastics Industries

Flour Mills, Feed Production, and Food Processing Plants

Thermal Power Stations and Energy Production Facilities

Woodworking and Furniture Manufacturing Plants

Industrial Dust Collection Systems and OEM Filter Units

Key Considerations When Selecting a Pulse Valve Timer Controller

Choosing the correct controller directly impacts the overall efficiency of the filtration system.

The following factors should be considered:

Total Number of Pulse Valves

The controller should provide sufficient output channels for current requirements and future system expansion.

Operating Voltage

Compatibility with existing solenoid coils and power supplies (24 VDC or 220 VAC) must be ensured.

Environmental Conditions

For outdoor or dusty environments, suitable protection ratings such as IP65 or IP68 and appropriate operating temperature ranges should be considered.

Energy-Saving Requirements

If minimizing compressed air consumption is a priority, Differential Pressure (ΔP) control functionality should be included.